Flue Kits & Accessories

This table illustrates the flue configurations that are available for the Paloma Power Flued Gas Space Heaters and the kits required to construct each type of configuration.

KITS REQUIRED QUANTITY PART NO.
Standard Direct Flue Kit 1 PFK1000
If wall thickness is less than 230mm
add Wall/Ceiling Plate Kit PFK5500
   
 

KITS REQUIRED QUANTITY PART NO.
Sideways/Under Floor Flue Kit 1 PFK3000
Includes Standard Direct Flue Kit
(PFK1000 & 90 Deg Bend)
See note 5  
Extra Wide Back Cover Kit 1 PWSK001
Coaxial Flue Pipe Kit See note 2 PFK4000
Coaxial 45° & 90° Bend Kit See note 3 PFK5100
 

KITS REQUIRED QUANTITY PART NO.
Standard Direct Flue Kit 1 PFK1000
Condensate Trap Kit 1 PFK5000
Coaxial Flue Pipe Kit See note 2 PFK4000
Coaxial 45° & 90° Bend Kit See note 3 PFK5100
Wall/Ceiling Plate Kit 1 PFK5500
Vertical Flue Cowl Kit 1 (A only) PFK5200
 

KITS REQUIRED QUANTITY PART NO.
Vertical Internal Wall Flue Kit 1 PFK2000
Includes Manifold Assembly with 
90° Bend & Condensate Trap, 
4 x Coaxial Flue Pipe (PFK4000), 
Vertical Flue Cowl Kit (PFK5200), 
Wall Box Assembly Kit, Top Plate
bracket, Drain Tube, Clips & Screws
See note 4  
Coaxial Flue Pipe Kit See note 2 PFK4000
Coaxial 45° & 90° Bend Kit See note 3 PFK5100
 

Accessories

  • Extra Wide Back Cover Spacer Kit PWSK001 – for Sideways and Under Floor installations you will require a Paloma Wider Back Spacer kit. Use only with PFK3000. PWSK001 is suitable for Paloma models PRS-150, PRS-250 & PRS-250C.
     
  • Flue Terminal Guard Assembly Kit PFK5300 – a Stainless Steel Flue Terminal Guard is available to prevent the public or children coming in contact with the flue terminal.
     
  • Wall Plate Foam Seal Kit PFK5700 – for external sealing of Wall Plate on uneven weatherboard/cladding surfaces.
     
Notes:
  1. Maximum flue length for all flue configurations is 9 metres total.
  2. Coaxial flue pipe is 900mm long – Order as many as required for installation.
  3. Kit has 2 x 45° bends. Use 2 x 45° bends for each 90° bend. A maximum of two 90° bends is permissible for flue systems that terminate horizontally (direct extended, sideways, underfloor & horizontal external wall configurations). A maximum of three 90° bends is permissible for flue systems that terminate vertically (vertical external wall & vertical in-wall configurations). Direct sideways configurations (as depicted) do not require any bends unless they are required to be offset.
  4. PFK2000 – The use of a Vertical Internal Wall Flue kit will require an internal wall cavity depth of 90mm (minimum).
  5. Suitable for horizontal flue termination only. No vertical flue run is allowed. Condensation must drain to outside.